To configure C16 IP Settings using a network switch:


Attach the front face plate to the panel and connect a Cat6 or Cat5e cable to the Ethernet port on the back of the panel and connect the other end to a network switch.

Note: Connecting Ethernet with the front face plate removed may cause the SmartSwitch Controller PCB to become disconnected.


Connect a computer to the same network as the C16 panel.


Configure computer's IP settings:

 

IPv4:          192.168.123.122

Sub:           255.255.255.0

Gateway:  192.168.123.1

DNS:          192.168.123.1

DNS2:        8.8.8.8 


Navigate in a web browser to 192.168.123.123 


Enter the username: root

Enter the password: password 

Click on the “Administration” tab on the C16 Webpage.

Click “Network Settings” and change to desired network settings.

Click “OK”

Click back to the “Administration” tab and locate “Reboot”

Click “OK” to reboot.


To configure C16 IP Settings directly from a laptop:


Attach the front face plate to the panel and connect a Cat6 or Cat5e (crossover cable recommended) to the Ethernet port on the back of the panel.

Note: Connecting Ethernet with the front face plate removed may cause the SmartSwitch Controller PCB to become disconnected.


Connect the other end of the cable to the Ethernet port of a laptop.


Configure laptop IP settings:

 

IPv4:          192.168.123.122

Sub:           255.255.255.0

Gateway:  192.168.123.1

DNS:          192.168.123.1

DNS2:        8.8.8.8 


Navigate in a web browser to 192.168.123.123 


Enter the username: root

Enter the password: password 

Click on the “Administration” tab on the C16 Webpage.

Click “Network Settings” and change to desired network settings.

Click “OK”

Click back to the “Administration” tab and locate “Reboot”

Click “OK” to reboot.